Field Filtering
The EMIS-X FHIR Platform supports selective field filtering via the standard
FHIR _elements search parameter.
This allows consumers to request only the specific elements needed for their workflow, reducing bandwidth, serialisation overhead, and memory consumption.
Query Syntax
Section titled “Query Syntax”Specify a comma-delimited list of base resource element names in the _elements
query parameter:
GET /FHIR/R4/1/Patient/ern:emis:patient:uuid:1c0188f4-2787-f730-22ec-237d3ec27b48/Condition?_elements=id,code,clinicalStatusMandatory Fields
Section titled “Mandatory Fields”In accordance with the HL7 FHIR R4 specification, the server always includes
mandatory resource elements in the response even if they are omitted from
_elements:
resourceType: Identifies the resource schema.id: Unique resource identifier (when assigned).- Any element defined with a minimum cardinality of 1 (
1..1or1..*) in the underlying FHIR profile.
Example Response
Section titled “Example Response”Requesting _elements=id,code,clinicalStatus on a Condition resource:
{ "resourceType": "Condition", "id": "a2aa38e2-0738-4ba0-a8aa-f2faaf6ad0de", "clinicalStatus": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/condition-clinical", "code": "active" } ] }, "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "195967001", "display": "Asthma" } ] }}Elements not specified in _elements (such as verificationStatus, category,
severity, subject, onsetDateTime, recordedDate) are omitted from the
payload.
Limitations
Section titled “Limitations”_elementsapplies to top-level elements of the target resource. Deep field projections (such as filtering elements nested inside a complex backbone element) are not supported._elementscannot be used to exclude mandatory elements or compromise clinical safety requirements.