Definition
An Observation represents a coded entry in a patient’s EMIS Web care record,
such as a clinical finding or a recorded value. Each Observation carries a
SNOMED CT code and its status (final, or preliminary where EMIS Web marks
the entry as provisional). When available, issued is the time the entry became
available in the record, not the time the observation was taken.
Observations are always accessed in the context of a patient, identified by an
ERN of the form ern:{Vendor}:patient:{Type}:{Identifier} (for example
ern:emis:patient:uuid:{patient GUID} or
ern:nhs:patient:number:{NHS number}). The Observation id is the GUID of the
underlying EMIS record, returned in upper case.
Searching for a patient’s Observations returns EMIS observation, investigation
and value entries, as a searchset Bundle with up to 50 entries per page. When
more results are available the Bundle includes a next link containing a
cursor query parameter; pass that cursor to retrieve the following page. Every
read and search is recorded in the EMIS Web access audit.
A blood pressure reading is recorded in EMIS Web as an investigation with a
systolic and a diastolic reading beneath it. The API returns it as one
Observation, the blood pressure entry itself, whose two component elements
hold the readings in the order recorded in EMIS Web. The two readings are not
returned as separate Observations and cannot be read by their own ids (404 Not
Found). Other entries that have child records are returned as ordinary
Observations.
Profile
Section titled “Profile”Every Observation returned by the FHIR Platform declares the
https://fhir.partner.emis-x.uk/StructureDefinition/emis-x-observation-1
profile in meta.profile.
Endpoints
Section titled “Endpoints”Paths are relative to the FHIR Platform base URL. Every request needs a bearer
token with the listed scope. Responses are application/fhir+json by default,
or application/fhir+xml when requested in the Accept header. Errors are
returned as an OperationOutcome.
GET /R4/1/Patient/ern:{Vendor}:patient:{Type}:{Identifier}/Observation/{ObservationId}Returns a single Observation, by id, for the given patient.
- Scope:
fpx-obs.read - Returns: Observation
Parameters
Section titled “Parameters”| Name | In | Type | Required | Description |
|---|---|---|---|---|
Vendor |
path | string | Yes | The vendor for the patient identifier. Allowed values: emis, nhs, jhs, gha. Only emis (with Type uuid) and nhs (with Type number) currently resolve a patient; other valid combinations return 404 Not Found. |
Type |
path | string | Yes | The identifier type for the patient identifier. Valid combinations are emis:uuid, nhs:number, nhs:chi, nhs:hospital, nhs:hcn, jhs:ssn and gha:number; any other combination is rejected with 400 Bad Request. |
Identifier |
path | string | Yes | The patient identifier. For Type uuid this must be a non-empty GUID (the EMIS patient GUID); for Type number it must be a valid NHS number. |
ObservationId |
path | uuid | Yes | The id (GUID) of the Observation to return. |
_elements |
query | string | No | Comma-separated list of top-level elements to include in the response. id, meta and mandatory elements are always returned, and the resource is tagged as SUBSETTED. |
Example response
Section titled “Example response”{ "resourceType": "Observation", "id": "5F3A8C1E-2B4D-4E7A-9C61-0D8F7A3B1E20", "meta": { "profile": [ "https://fhir.partner.emis-x.uk/StructureDefinition/emis-x-observation-1" ] }, "language": "en", "status": "final", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "254063019", "display": "O/E - blood pressure reading" } ] }, "subject": { "reference": "650fa751-87d9-4543-9adb-7b0878dd0117", "type": "Patient" }, "issued": "2026-02-10T09:00:00+00:00", "component": [ { "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "114311000006111", "display": "Systolic blood pressure" } ] }, "valueQuantity": { "value": 120, "unit": "mm[Hg]" } }, { "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "619931000006119", "display": "Diastolic blood pressure" } ] }, "valueQuantity": { "value": 80, "unit": "mm[Hg]" } } ]}Search
Section titled “Search”GET /R4/1/Patient/ern:{Vendor}:patient:{Type}:{Identifier}/ObservationReturns all Observations for the given patient as a paged searchset Bundle.
- Scope:
fpx-obs.read - Returns: Bundle of Observation
Parameters
Section titled “Parameters”| Name | In | Type | Required | Description |
|---|---|---|---|---|
Vendor |
path | string | Yes | The vendor for the patient identifier. Allowed values: emis, nhs, jhs, gha. Only emis (with Type uuid) and nhs (with Type number) currently resolve a patient; other valid combinations return 404 Not Found. |
Type |
path | string | Yes | The identifier type for the patient identifier. Valid combinations are emis:uuid, nhs:number, nhs:chi, nhs:hospital, nhs:hcn, jhs:ssn and gha:number; any other combination is rejected with 400 Bad Request. |
Identifier |
path | string | Yes | The patient identifier. For Type uuid this must be a non-empty GUID (the EMIS patient GUID); for Type number it must be a valid NHS number. |
_elements |
query | string | No | Comma-separated list of top-level Observation elements to include in each Bundle entry. id, meta and mandatory elements are always returned, and each shaped entry is tagged as SUBSETTED. |
cursor |
query | string | No | Opaque paging cursor taken from the Bundle’s next or previous link. Omit to retrieve the first page (50 entries). |