Skip to content
Partner Developer Portal

Schema

Elements of Observation that the FHIR Platform populates or constrains. Elements not listed here are not populated.

Element Type Cardinality Description
Observation.id id 1..1 The GUID of the EMIS Web observation record, in upper case.
Observation.meta Meta 1..1 Resource metadata.
Observation.meta.profile canonical 1..1 The EMIS-X Observation profile the resource conforms to.
Allowed values: https://fhir.partner.emis-x.uk/StructureDefinition/emis-x-observation-1
Observation.language code 1..1 The language of the resource. Always en (English).
Allowed values: en (English) (system: urn:ietf:bcp:47)
Observation.status code 1..1 preliminary when the entry is marked as provisional in EMIS Web, otherwise final.
Binding (required): http://hl7.org/fhir/ValueSet/observation-status
Allowed values: final (Final), preliminary (Preliminary)
Observation.code CodeableConcept 1..1 The clinical code recorded for the entry.
Observation.code.coding Coding 1..1 A single SNOMED CT coding for the entry.
Observation.code.coding.system uri 1..1 Always http://snomed.info/sct.
Observation.code.coding.code code 1..1 The SNOMED CT concept id recorded in EMIS Web. If the record has no code, 37331000000100 (Comment note) is returned.
Observation.code.coding.display string 1..1 The term as originally recorded by the clinician in EMIS Web. If no term was recorded, Comment note is returned.
Observation.subject Reference(Patient) 1..1 The patient the observation belongs to.
Observation.subject.reference string 1..1 The EMIS patient GUID (lower case), without a resource type prefix.
Observation.subject.type uri 1..1 Always Patient.
Observation.issued instant 0..1 The date and time the entry became available in the EMIS Web record.
Observation.value[x] Quantity or string 0..1 Numeric results take precedence over text results and are returned as valueQuantity, with a comparator for <, <=, >= or >. Other recorded operators produce valueString containing the operator, value and units. Without a numeric result, recorded text is returned as valueString. Quantities preserve the trimmed recorded unit; UCUM system and code are included only for recognised units. Omitted when neither a numeric nor a non-blank text result is recorded.
Observation.component BackboneElement 0..* The two readings of a blood pressure entry, systolic and diastolic, in the order recorded in EMIS Web (which is not always systolic first). Only returned for a recognised blood pressure entry; omitted for every other Observation.
Observation.component.code CodeableConcept 1..1 What the reading measures, for example systolic or diastolic blood pressure.
Observation.component.code.coding Coding 1..1 A single SNOMED CT coding for the reading, following the same rules as Observation.code.coding.
Observation.component.value[x] Quantity or string 0..1 The recorded reading as valueQuantity, with a comparator when one was recorded. The unit is always mm[Hg] and no UCUM system or code is returned. A reading recorded with an operator that is not a FHIR comparator is returned as valueString instead, and a text-only reading as valueString. Omitted when the reading has no value.