Schema
Elements of Observation that the FHIR Platform populates or constrains.
Elements not listed here are not populated.
| Element | Type | Cardinality | Description |
|---|---|---|---|
Observation.id |
id | 1..1 | The GUID of the EMIS Web observation record, in upper case. |
Observation.meta |
Meta | 1..1 | Resource metadata. |
Observation.meta.profile |
canonical | 1..1 | The EMIS-X Observation profile the resource conforms to. Allowed values: https://fhir.partner.emis-x.uk/StructureDefinition/emis-x-observation-1 |
Observation.language |
code | 1..1 | The language of the resource. Always en (English).Allowed values: en (English) (system: urn:ietf:bcp:47) |
Observation.status |
code | 1..1 | preliminary when the entry is marked as provisional in EMIS Web, otherwise final.Binding (required): http://hl7.org/fhir/ValueSet/observation-statusAllowed values: final (Final), preliminary (Preliminary) |
Observation.code |
CodeableConcept | 1..1 | The clinical code recorded for the entry. |
Observation.code.coding |
Coding | 1..1 | A single SNOMED CT coding for the entry. |
Observation.code.coding.system |
uri | 1..1 | Always http://snomed.info/sct. |
Observation.code.coding.code |
code | 1..1 | The SNOMED CT concept id recorded in EMIS Web. If the record has no code, 37331000000100 (Comment note) is returned. |
Observation.code.coding.display |
string | 1..1 | The term as originally recorded by the clinician in EMIS Web. If no term was recorded, Comment note is returned. |
Observation.subject |
Reference(Patient) | 1..1 | The patient the observation belongs to. |
Observation.subject.reference |
string | 1..1 | The EMIS patient GUID (lower case), without a resource type prefix. |
Observation.subject.type |
uri | 1..1 | Always Patient. |
Observation.issued |
instant | 0..1 | The date and time the entry became available in the EMIS Web record. |
Observation.value[x] |
Quantity or string | 0..1 | Numeric results take precedence over text results and are returned as valueQuantity, with a comparator for <, <=, >= or >. Other recorded operators produce valueString containing the operator, value and units. Without a numeric result, recorded text is returned as valueString. Quantities preserve the trimmed recorded unit; UCUM system and code are included only for recognised units. Omitted when neither a numeric nor a non-blank text result is recorded. |
Observation.component |
BackboneElement | 0..* | The two readings of a blood pressure entry, systolic and diastolic, in the order recorded in EMIS Web (which is not always systolic first). Only returned for a recognised blood pressure entry; omitted for every other Observation. |
Observation.component.code |
CodeableConcept | 1..1 | What the reading measures, for example systolic or diastolic blood pressure. |
Observation.component.code.coding |
Coding | 1..1 | A single SNOMED CT coding for the reading, following the same rules as Observation.code.coding. |
Observation.component.value[x] |
Quantity or string | 0..1 | The recorded reading as valueQuantity, with a comparator when one was recorded. The unit is always mm[Hg] and no UCUM system or code is returned. A reading recorded with an operator that is not a FHIR comparator is returned as valueString instead, and a text-only reading as valueString. Omitted when the reading has no value. |